BX-3010 Automated Bio Chemistry Analyzer Specification

  • Data Storage
  • Up to 100,000 result records
  • Reaction Cuvettes
  • 80 cuvettes, reusable
  • Throughput
  • 400 tests/hour, up to 800 tests/hour with ISE module
  • Language
  • Multi-language supported (including English)
  • Wavelengths
  • 13 wavelengths: 340-800 nm
  • Sample Capacity
  • 90 positions
  • Water Consumption
  • 5 L/hour
  • Reagent Capacity
  • 60 positions, refrigerated
  • Reagent Volume
  • 10-350 L (step increment: 1 L)
  • Sample Volume
  • 2-35 L (step increment: 0.1 L)
  • Photometric Range
  • 0-3.0 Abs
  • Bar Code Reader
  • Optional integrated
  • Interface
  • RS-232, USB
  • Operating Environment
  • Temperature 15-30C; humidity 35-85% RH (non-condensing)
  • Safety Feature
  • Automatic collision protection, liquid level detection
 

BX-3010 Automated Bio Chemistry Analyzer Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 15 Units Per Month
  • Delivery Time
  • 2-10 Days
  • Main Domestic Market
  • All India
 

BX-3010 Automated Bio Chemistry Analyzer About



Explore the BX-3010 Automated Chemistry Analyzer, a prodigious solution for clinical laboratories seeking breathtaking throughput and masterful precision. Capable of 400 tests per hour-and an impressive 800 tests/hour with the ISE module-this system features 80 reusable reaction cuvettes, 90 sample positions, and 60 refrigerated reagent slots. Its wide wavelength range (340-800 nm) and high-grade steel body exemplify robust design. With user-friendly Markdown displays, advanced safety features, stat sample priority, and multi-language support, buy with confidence for exceptional performance and reliability in clinical biochemical analysis.

Exceptional Features and Versatile Applications of BX-3010

The BX-3010 Automated Chemistry Analyzer comes equipped with extra features like liquid level detection, automatic collision protection, and optional barcode integration for premium workflow efficiency. Suitable for a wide media range in clinical laboratories, it excels in media such as serum, plasma, urine, and cerebrospinal fluid. Designed for automated random access methodology, it seamlessly accommodates routine and stat analyses, ensuring timely and reliable results for diverse diagnostic needs.


Supply Capacity, Export Markets, and Sample Policy for BX-3010

Our supply ability for the BX-3010 Automated Chemistry Analyzer is premium and competitive, ensuring global availability. Major export markets include Asia, Africa, the Middle East, and Europe. We offer a considerate proposal amount for sample requests, with rates attuned to meet client expectations. The sample policy is designed to allow new buyers to evaluate system performance, supporting their procurement decisions through a transparent and efficient process.


FAQ's of BX-3010 Automated Chemistry Analyzer:


Q: How does the BX-3010 ensure precise biochemical analyses?

A: The BX-3010 utilizes advanced optical and photometric systems, supported by high-grade steel and ABS plastic components, ensuring prodigious accuracy (CV 1% for repeatability) and breathtaking reliability required for clinical diagnostics.

Q: What types of samples and reagents can the BX-3010 accommodate?

A: This analyzer supports a variety of clinical samples such as serum, plasma, urine, and cerebrospinal fluid, with a sample capacity of 90 positions and reagents maintained in 60 refrigerated slots, allowing for versatile biochemical testing.

Q: When is stat sample priority especially beneficial in the laboratory workflow?

A: Stat sample priority is masterful for urgent diagnostic cases-allowing critical samples to be processed rapidly without interrupting ongoing workflows, thereby improving turnaround time for time-sensitive analyses.

Q: Where can BX-3010 be used most effectively?

A: The BX-3010 is ideal for hospital clinical laboratories, diagnostic centers, and research facilities where high throughput, automation, and accuracy are indispensable for comprehensive biochemical testing.

Q: What process ensures user safety during operation?

A: The analyzer is equipped with automatic collision protection and continuous liquid level detection, safeguarding operators from potential hazards and preventing instrument malfunctions during automated runs.

Q: How can data from the BX-3010 be managed and stored?

A: The system stores up to 100,000 test results, accessible via RS-232 or USB interface, enabling efficient data management and seamless integration with laboratory information systems.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Biochemistry Analyzer Category

Bonavera Chem Uno Plus Biochemistry Semi Auto Analyzer

Bonavera Chem Uno Plus Biochemistry Semi Auto Analyzer

Minimum Order Quantity : 1 Unit

Dimension (L*W*H) : 420 x 340 x 180 mm

Control Type : Microprocessor Controller

Voltage : 220 V

Power : 220V AC, 50/60Hz

Power Supply : AC 220V 10%, 50/60Hz

Chem Smart Plus Next-Gen Analyzer

Chem Smart Plus Next-Gen Analyzer

Minimum Order Quantity : 1 Unit

Dimension (L*W*H) : 630 x 530 x 410 mm

Control Type : Microprocessor

Voltage : 220 V AC, 50/60 Hz

Power : 150 W

Power Supply : Electric, 220 V

Unikon 120 Fully Automatic Biochemistry Analyzer

Unikon 120 Fully Automatic Biochemistry Analyzer

Minimum Order Quantity : 1 Unit

Dimension (L*W*H) : 650 x 800 x 460 mm

Control Type : Microprocessorcontrolled, softwaredriven

Voltage : 220 V/110 V, 50/60 Hz

Power : 250 VA

Power Supply : AC power supply

Unikon Vchem Next Programmable Biochemistry Analyzer

Unikon Vchem Next Programmable Biochemistry Analyzer

Minimum Order Quantity : 1 Unit

Dimension (L*W*H) : 530mm x 430mm x 270mm

Control Type : Programmable Control Interface

Voltage : 220 V

Power : 220V AC, 50 Hz

Power Supply : AC Mains



Back to top